rAPID-T Discrete Analyzer
The rAPID-T software/hardware platform offers a compact, affordable automated Chemistry Analyzer.
- Durable. Accurate. Precise. Economical
- Open software platform. Program it to run:
- Tests for NO2, NO3, Ammonia, Ortho-Phosphate, TKN, TPhos, Cyanide, Phenol, Sulphate, Hexavalent Chromium, etc.
- Wine tests (Acetic Acid, Malic Acid, etc.) from many manufacturers
- Beer Kits (Acetaldehyde, Sulfite, etc.) Download brochure.
- Colorimetric tests currently being run manually
- Up to 100+ tests per hour with 10mm path length cuvettes
- Built-in temperature controlled reactions
- Wavelengths: 340, 405, 420, 480, 505, 540, 570, 660 or … custom
- Small footprint and weight: 21” W x 15.5” H x 20” D and 37 pounds!
- Compatible with Windows Vista or 7/8/10 (computer not supplied)
The software optimizes the rAPID-T's advanced hardware and performance. Operators can program their colorimetric applications into rAPID-T’s easy-to-use method setup and configurations. Because of rAPID-T’s open platform, operators can also adapt their system to use assay kits for Water, Wine, Food and other analyses from several manufacturers (e.g. Megazyme, Bio-Rad, Thermo Scientific, NZYTech, Nitrate Elimination Company, etc.)
Specifications
Typical throughput |
up to 100+ tests per hour |
Typical reaction volume |
250 µL |
Path length of cuvette |
10mm |
Reaction vessel |
5-well cuvettes, disposable |
Maximum reaction volume |
500 µL |
Dimensions |
21” (53cm) W x 15.5” (40cm) H x 20” (50 cm) D |
Weight |
37 lbs (17 kg) |
Reagent and Sample Handling
Syringe |
500 μL, range 2 μL – 450 μL w/increments of 0.5 μL |
Probe |
316 stainless steel w/liquid level sensing |
Mixing |
Probe oscillation, time and speed adjustable |
Precision for volumes < 5 μL |
< 3% CV |
Precision for volumes > 5 μL |
< 2% CV |
No. of reaction cuvette places |
40 w/PAUSE feature to allow operator to add more during a run |
No. of reagent places |
10 Total: 15 mL and 30 mL |
No. of sample places |
40 places for 4 mL sampler cups w/PAUSE feature to add additional samples during a run |
Reaction temperature |
From ambient to 40⁰C |
|
Incubation is software controlled and automatically optimized |
Reading
Optical design |
User-selected monochromatic or bichromatic results |
|
8-position filter wheel |
|
Wavelengths: 340, 405, 420, 480, 505, 540, 570, 660 or custom |
Interference filters |
Long life, hard coat, ion assisted deposition, ~10nm half bypass |
Linear range |
0.0 to 3.0 A |
Photometer accuracy |
+ (1% reading + 0.005A) from 0 to 1.0 A |
|
+ (2% reading + 0.005A) from 1.0 A to 3.0 A |
Software
Format |
USB with internet upgrades |
QC Functions |
Store Control Data, QC Data Charting Screen |
Operating system |
Windows® 7, 8, 8.1 or 10 Professional |
System Diagnostic Tools |
Probe/Rack Alignment, Control Scripts, Self-Test, QC Well |
Self-monitoring modes |
Lamp, filters, reagent levels, Cuvette |
Certifications
NRTL listed (Canada and US), CE marked